What should receiving check on a reefer trailer at the gate?

For receiving, gate and quality teams handling temperature-controlled loads.

Reviewed September 26, 2026 · sources linked inline

Short answer: at the gate, check that the reefer's set point matches the temperature the shipper specified, that the unit is running without alarms, and the fuel level if the trailer will sit. Record the readings with the time, then spot it where it can be powered or watched. The FDA's Sanitary Transportation rule expects receivers of temperature-controlled food to “take steps to adequately assess that the food was not subjected to significant temperature abuse” (21 CFR 1.908(d)).

What the FDA rule asks of each party

The FDA's Sanitary Transportation of Human and Animal Food rule (21 CFR Part 1, Subpart O) splits responsibilities between shippers, loaders, carriers and receivers. The section on transportation operations, 21 CFR 1.908, says:

PartyRequirement (quoted from 21 CFR 1.908)
ShipperMust "specify in writing to the carrier… an operating temperature for the transportation operation including, if necessary, the pre-cooling phase" (§1.908(b)(2))
LoaderMust verify that each refrigerated compartment "is adequately prepared for the transportation of such food, including that it has been properly pre-cooled, if necessary" (§1.908(c)(2))
CarrierWhere the carrier and shipper have a written agreement making the carrier responsible for sanitary conditions: once the trip is complete and if the receiver asks, provide the operating temperature the shipper specified and, if the shipper or receiver asks, "demonstrate that it has maintained temperature conditions during the transportation operation consistent with the operating temperature" (§1.908(e)(2))
ReceiverMust "take steps to adequately assess that the food was not subjected to significant temperature abuse, such as determining the food's temperature, the ambient temperature of the vehicle and its temperature setting, and conducting a sensory inspection" (§1.908(d))

Two practical points follow. You need the specified temperature to check against, and it comes from the shipper, so get it on the BOL or load instructions. And the rule already names the reefer's temperature setting as one of the things a receiver can assess, which is easiest to read while the driver is still at the gate.

The rule has exemptions and specific definitions (for example for certain small businesses and food types). Check whether and how it applies to your operation.

Gate checklist for a reefer

On top of your normal gate fields (time in, carrier, trailer number, seal, driver):

Spotting and yard checks

Spot reefers near power if you have plug-in spots, or where the gate or dock can see them. Add a temperature column to the yard check for reefers and note set point, reading and time on each walk. When reefers have been waiting, especially with low fuel, move them up the door list.

At the door

The gate check does not replace the receiving assessment. At the door, receiving typically checks product temperatures against your acceptance criteria, looks at any temperature record that was requested or provided, and does a sensory inspection for thawing, off-odors or damage. Whatever you check, write down what you found and when: if the load is later rejected or disputed, the gate line and the door record together show when the problem started.

Common gaps

General information, not legal or regulatory advice. Confirm how 21 CFR Part 1, Subpart O applies to your operation.

Frequently asked questions

Who sets the temperature for a reefer load?

The shipper. Under 21 CFR 1.908(b)(2), the shipper must specify an operating temperature in writing to the carrier, including pre-cooling if necessary.

Can the receiver ask for the reefer's temperature history?

Where the carrier has agreed in writing to be responsible for sanitary conditions, 21 CFR 1.908(e)(2) says the carrier must, if the shipper or receiver asks, demonstrate that it maintained temperature conditions consistent with the specified operating temperature.

Should we reject a reefer if the set point is wrong?

Not automatically. Flag it, check product temperatures at the door, follow your acceptance procedures, and record what you found either way.